ULTRASONIC FLAW DETECTOR  >>  da Vinci alpha
 
   >>
IP67 sealing compliance
>>
Rotary knobs for analogue feeling
>>
Test Range: 2.5mm to 10 meters (Steel)
>>
Different colours for change of leg(weld testing)
>>
RF display for better measurement accuracy and flaw characterization
>>
Measurement resolution of 0.01mm
>>
Thro' coating thickness measurement
>>
Auto Calibration/Two point calibration
>>
Dynamic DAC,DGS/AVG,TCG features and AWS software
 
 Technical Specification - ( da Vinci alpha )
Test Range :

2.5 mm to 10 meter(0.100 in to 400 in) (steel).

Velocity : 1000 meters/second to 15000 m/sec(40 in/millisec to 600in/millisec).In Hot key mode it has preset values.
Gain : 100 dB Calibrated Gain adjustable in 0.1,  0.5,1,2,6, or 12 dB step
Rectification :

Full wave,Half wave-ve,Half wave +ve and RF mode.

Frequency :

It has tuned amplifier with Four Bands:(a) 0.2 MHz to 1MHz (b) 0.5 MHz to 4 MHz.(c) 0.8MHz to 8MHz(d) 2MHz to 20MHz

Transmitter : Transmission pulse Negative spike.(Pulse Rise Time<10ns) and with selectable high(300Vp) or low (250Vp) power.
Damping : Damping high/low is selectable.(High= 45ohms,Low=345ohms)
Freeze/Peak Freeze :

A-Scan Freeze, Peak Freeze,Active Echo dynamic available.

Monitor : Dual gates adjustable in 1% of Screen width with positive/Negative logic, Gate Expand,Interface trigger modes.
Gate Expand : Expand Range to width of the gate.
A-Scan memory : 500 Trace Patterns can be stored(with Note/Detail) which can be recalled, printed or transferred to PC via USB port. Unlimited no.of A-Scan can be directly stored in USB Disk with auto file naming
Calibration Set-up : 50 different calibration set-ups can be Stored and Recalled.
Software : dvaSoft  interface software for transferring A-Scan/B-Scan/T-LOG from da Vinci alpha to PC is supplied as standard equipment.it also creates sequential,2D and 3D configured files for thickness logging
Display : High brightness Colour TFT LCD Display. Display area 320x240 pixel (117 x88mm). Five different colour and Grid scheme options. Colour leg facility for angle probe for easy interpretation of skip distance
Reference A-Scan : Reference A-Scan pattern of standard test object can be saved and recalled in the background for easy comparison during testing.
DAC : Dynamic DAC curve can be Digitally plotted(Smooth parabolic curve) on screen  with selectable additional offset curves From 0 to 14db in 0.1db selectable steps. DAC curve can be plotted using  minimum 2 to maximum 10 points .
DGS : Defect size evaluation based on 18 predefined probe data and one custom probe set-up per memory location. Defect size is directly displayed in ERS value(Equivalent Reflector Size).
AWS : Built-in software for evaluation of defects in accordance with AWS Standards.(AWAD1.1/D1.5)

Digital Readout and Trig. Function

: Thickness/Depth can be displayed in digital readout when using a normal probe and Sound path, Surface Distance and Depth of echo signals of GATEa / GATEb  are directly displayed when angle probe is in use. Measurement point can be selected to be Peak or Flank. Echo height,ERS value,dB diff of DAC/ DGS curve to single height, Echo height with respect to DAC in terms of percentage or in dB can be measured,T-Minimum,Travel distance can be measured when encoder is connectd and time of travel during Freerun B-Scan.
Measurement Unit : Metric or British unit of measurement is selectable.
Video output : VGA  video signal output for connecting to monitor/LCD projector.
PRF : 4Hz to 500Hz,Selection in 10 scalable steps.PRF can go down up to 4Hz when PRF is selected to 1..
Updating Rate : 60Hz.
Power : Lithium-Ion Battery pack10.8VDC,7.8AH,give 8 hours continuous operation from fully charged battery.Battery with the charge indicator/fuel gauge indicator.da VINCI ALPHA CAN ALSO OPERATE ON 6 nos.of . C type dry cells
Charger : Input Voltage 100 to 240 VAC/50Hz.
Temperature : 0 to 55° C.
Size/Weight : 170x260x110 mm ( HxWxD )/2.3Kgs. With battery
(Modification rights reserved)