Products : Advanced
TD Advanced Ultrasonic Software |
|

1. All Product List
2. Advanced Product List |
| |
|
|
 |
Features |
Applications |
Intuitive user friendly menus |
Pressure Vessels Welds |
Powerful, easy to use analysis tools |
Pipeline Welds |
Fully integrated TOFD, Pulse Echo and Phased Array |
Structural Welds |
Ideal for manual, semi & automated inspections |
Forgings & Castings |
One software suite for all instruments in the TD range |
Turbine Disks & Blades |
Unrivalled performance. |
Aircraft Components |
Real-time A, B, C, D & S-scan imaging |
Hydrogen Damage Surveys |
Weld geometry overlays |
Corrosion Surveys |
TD Super-View for complete user controlled imaging |
|
Techniques |
Software Options |
Phased Array |
Phased Array / Pulse Echo |
ToFD |
ToFD |
Pulse Echo |
Strip-Scan |
Corrosion Mapping |
Long Range (CHIME®) |
|
TD Super-View® |
TD-Scan Software Specification & Features
General |
Easy to use Windows XP Pro® based software provides a fully integrated TOFD, Pulse Echo and Phased Array capability in our tough, feature rich portable ultrasonic acquisition units. Ideally suited to either semi automated or automatic inspection, whether you are using the miniature TD Pocket-Scan, TD Handy-Scan, TD-Scan or our top-of-the-range TD Focus-Scan, our Advanced Ultrasonic Software provides unrivalled performance.
Intuitive user friendly menu’s guide the user through each operation, with all parameters definable on a channel by channel basis. With our TD-Scan and TD Focus-Scan units the software can also be controlled by shortcut keys integrated into the front panel to provide mouse-free operation.
Our software provides real-time A, B , C, D & S-scan imaging with probe angle and geometry (skip) correction performed on-line and off-line. The user is provided instantly with a true representation of the material under test and with our enhanced analysis tools the process of defect interpretation and condition assessment is smooth and remarkably quick TD Super-View® was developed with the operator in mind: that means, full control of the data display online and offline. The operator has the flexibility of choice to divide the main display window into 4 display areas and further subdivide each display area into multiple sub-areas presenting A, B,C,D or S scans on the screen as desired. The operator has the choice of displaying the above data from individual channels or as a composite view of all active channels. Data from different scan modes can also be viewed simultaneously, for instance ToFD and Pulse Echo data from different channels can be viewed. The Choice is Yours!
Our CommsBridge software is a small application that allows you to control either the TD-Scan or the Focus-Scan units remotely across an Ethernet link. This is useful for analysing data at a remote location using your corporate network or if you use your unit as a ‘black box’. |
Hardware Setup Controls |
Channel number |
128 Software channels |
Channel Mode |
Phased Array, ToFD, Pulse echo |
Pulse Width |
Enter probe frequency—auto calculate |
Amplifier Control |
Gain—user controlled
Select number of TCG (max 8) |
| TX/RX |
Control Select probe connections |
| Digitiser Control |
8 or 14 Bits per sample
Up to 200Mhz sample rate
Up to 256 averaging |
Probe Setup Controls |
Array Geometry |
Linear |
Probe Angle |
User defined |
Wave Type |
Shear, Compression |
Probe Delay |
Millimetres or microseconds |
Direction (Skew) |
User defined in relation to a centre line |
Strip-Scan |
Active when Strip-Scan selected in ‘Scanner |
| Offsets |
Horizontal—distance from centreline, Vertical—distance from adjacent probe |
| Skip Correction |
Flat Geometry |
| Balance Elements |
Phased array only—response homogenisation |
| Apodization |
None, Hamming, Gaussian, Blackman-Harris |
Gate Controls |
Peak Time |
Gate Crossing, Peak tip |
I/F Trigger |
Off—no interface trigger
On—interface trigger activated for emersion |
I/F Trigger Setup |
On, Off |
A-scan mode |
Off, Always, If Peak in Gate |
| Peak Mode |
Off. All Peaks, First-Thinnest, First-Thickest
Between, Between-Thinnest
Between-Thickest, Loss of Signal |
Filters |
Rectifier |
Disabled(RF), Full wave,
Half wave-, Half wave+ |
Filter |
Post rectification signal smoothing |
Low Pass Filter |
User selectable |
| High Pass Filter |
User selectable |
Focal Law Generator (F-Law) - Phased Array only |
Focus Mode |
Range, Horizontal, Vertical
|
TX Control |
First Active element
Number of active elements
Index points/Stride
Focal range
Element 1 connection |
Wedge Parameters |
On, off
First Element at—Top or Bottom
First element height
First element to diffuser
Angle (of probe face to scan surface)
Ultrasonic velocity of wedge |
Manual Delay Entry |
On, Off |
RX Control |
First Active element
Number of active elements
|
Dynamic Focussing |
Focal Range Minimum & Maximum |
| Angle Emission point override |
User defined adjustments |
| Angle Control |
Swept, Fixed |
| Swept angle (Sectorial) |
Minimum/maximum angle, angular Step |
| Fixed Angle |
Tx / Rx angles |
| Focal Law Balancing |
Interactive procedure to equalise amplitude across a range of focal laws |
| |
|
| Other |
Time Corrected Gain |
8 curves (1 per channel) |
Image Colour Pallets |
Amplitude, depth, user definable |
Import Setups |
From setup file or existing scan file |
| Report Generator |
User definable headings & input text & scan image printing |
| TD Super-View |
User defined data presentation on & offline |
| Scanner Controls |
Manual Input |
Manual un-encoded scanning |
XY Raster (Dual Axis) |
Semi & automated, encoded or free run |
Arm Scanner |
Dual axis rotating arm scanners for corrosion mapping |
Motion Control |
PID Loops for accurate positional control |
| Single Axis |
Semi & automated, encoded or free run |
| Rotational / Radial |
Semi & automated tube scanning |
| Video Tracking |
Track probe position using video camera for corrosion
mapping |
| Data Analysis |
TD Super-View
- A,B,C,D & S scan, P/E, P/A, ToFD
- User definable panel configuration for data images
- View data from multiple channels individually or over-layed
- Image filtering, zoom functions
- Corrected skip overlay
- User definable weld overlays
- Defect sizing by cursors or echo-dynamic
- Off-line gain control
- Dynamic sizing range up to 400% FSH
- Output data as text Depth, Range, Amplitude, angle, Channel, focal, Law, distance information in real time
- C-scan gate let you pinpoint areas of interest
|
Normal Data |
Strip-Scan |
Zone discrimination for pipelines |
Presentation |
ToFD
Pulse Echo
Long Range(CHIME®) |
Full ToFD analysis
Corrosion Mapping, Welds
Corrosion mapping |
ToFD |
Straighten, linearise, SAFT, lateral/backwall removal contrast, parabolic cursors, overlay text, echo-dynamic, file split/join, data reversal, create bitmap, output data as text |
Strip-Scan |
Views (time/amplitude, map, off, volumetric channels, couplant check, Go/no-go), auto defect mark-up & size calculation |
Corrosion Mapping |
Single/Dual cursors, C-scan +end views, Min/Max values, output data as text, Re-gate, Change colours, View control (peak modes, pixel size), text overlay, join files, save bitmap |
|
|
|
|
|
|
| | | | | | | | | | | | | |
|
Modsonic Instruments Manufacturing Company Pvt. Ltd.
Plot 33, Phase III, GIDC Industrial Estate, Naroda, Ahmedabad - 382330. INDIA.
Phone : +91 (79) 22811217 +91 (79) 22811217, 22813131, 22841294, Fax : +91 (79) 22820012
Email : , Website :
This website is a property of Modsonic Powered & Designed by :
|
|
|
|