Test AT welded rail joint in less than 10 minutes...
| TECHNICAL SPECIFICATION |
| Test Range |
10 mm to 5 meter (in steel) adjustable in 1mm or 10mm step. |
| Velocity |
1000 m/s to 9999 m/s adjustable in 1 m/s or 10 m/s step. |
| Delay |
Up to 3 meter adjustable in 0.5mm or 5mm step. |
| Gain |
100 dB calibrated gain adjustable in 0.5, 1, 2, 6, 12 or 20 dB step. |
| Rejection |
0 to 100% FSH with LED indicator. |
| Rectification |
Fullwave rectified with filtering. |
| Frequency |
0.5 MHz to 10 MHz (Wideband). |
| Test Modes |
Pulse echo and transmit/receive. |
| Connectors |
BNC |
| Monitor |
Dual gate adjustable in 1% of Screen width with Positive/Negative logic, Gate Expand modes. |
| Gate Expand |
Expands Range to width of the gate. |
| A-Scan memory |
200 Trace Patterns can be stored, recalled, print or transferred to PC via RS-232 serial port. |
| Calibration Set-up |
Special memory set-up allotted for Rail weld testing for easy set-up recall and testing. Total 50 calibration set-ups can be Stored and Recalled. |
| Tandem Technique |
Special Test-Rig for tandem technique is provided for the Rail weld joint examination. |
| Probe |
Complete set of probes are provided for the Rail weld examination. |
| Software |
EinSoft Interface software for transferring A-Scan from Einstein-II(AT) to PC is supplied. |
| Printer Attachment |
Any PC Printer with serial port can be attached for instant print-out of Trace Pattern (A-Scan with Set-up data). |
| Display |
High brightness colour TFT LCD display. Display area 122x92 mm (320x240 pixel). Eleven different colour scheme options. |
| Full Screen |
By pressing Zoom key A-Scan can be displayed in Full Screen area. |
| Reference A-Scan |
Reference A-Scan pattern of standard test object can be saved and recalled in the background for easy comparison during testing. |
| DAC |
DAC curve can be Digitally plotted on screen. DAC curve can be set as flaw monitor gate. |
| Digital Readout And Trig.Function |
Thickness/Depth can be displayed in digital readout when using a normal probe and Beam path, Surface Distance and Depth are directly displayed when angle probe is in use. |
| Power |
Lithium-Ion Battery pack 14.4VDC,4AH, gives 8 hours continuous operation from fully charged
battery. Full charging is done within 4½ hours. |
| Charger |
Input Voltage 100 to 240 VAC. Charge status indicator is provided. |
| Temperature |
0 to 55° C. |
| Size |
152 x 255 x 70 mm (HxWxD). |