RDSO Approved (Specification No. M&C/NDT/128/2007)
TECHNICAL SPECIFICATION |
Ultrasonic Flaw Detector |
Test Range |
10 mm to 5 meter (in steel) adjustable in 1mm or 10mm step. |
Velocity |
1000 m/s to 9999 m/s adjustable in 1 m/s or 10 m/s step |
Delay |
Up to 3 meter adjustable in 0.5mm or 5mm step. |
Gain |
80 dB calibrated gain adjustable in 0.5,1,2,6,12 or 20 dB step. |
Rejection |
0 to 100% FSH with LED indicator. |
Rectification |
Fullwave rectified with filtering |
Frequency |
0.5 MHz to 10 MHz (Wideband). |
Test Modes |
Pulse echo and transmit/receive. |
Connectors |
BNC and Lemo(Size1) both are provided. |
Monitor |
Dual gate adjustable in 1% of Screen width with Positive/Negative logic, Gate Expand modes. |
Gate Expand |
Expands Range to width of the gate. |
A-Scan memory |
200 Trace Patterns can be stored, recalled, print or transferred to PC via RS-232 serial port. |
Calibration Set-up |
Total 50 Calibration set-ups can be Stored and Recalled |
Probe |
Complete set of probes provided for the Rail examination. |
| Software |
RailSoft-100 Interface software for transferring A-Scan from "RailScan-100" to PC is supplied. |
Printer Attachment |
Any PC Printer with serial port can be attached for instant print-out of Trace Pattern (A-Scan with Set-up data). |
Display |
High brightness colour TFT LCD display. Display area 122x92 mm (320x240 pixel). Eleven different colour scheme options. |
Peak Freeze |
Peak freeze it holds echo dynamic pattern which is useful during angle beam
probing to locate peak signal. |
Full Screen |
By pressing Zoom key A-Scan can be displayed in Full Screen area. |
Reference A-Scan |
Reference A-Scan pattern of standard test object can saved and recalled in the background for easy comparison during testing. |
DAC |
DAC curve can be Digitally plotted on screen. DAC curve can be set as flaw monitor gate. |
Digital Readout and Trig. Function |
Thickness/Depth can be displayed in digital readout when using a normal probe and Beam path,
Surface Distance and Depth are directly displayed when angle probe is in use. |
Power |
Lithium-Ion Battery pack 14.4VDC,4AH, gives 8 hours continuous operation from fully charged
battery. Full charging is done within 4 ½ hours. |
Charger |
Input Voltage 100 to 240 VAC. Charge status indicator is provided. |
Temperature |
0 to 55°C. |
Size |
152 x 255 x 70 mm (HxWxD). |
Weight |
2.3 Kgs. with Battery. |
MULTIPLEXER |
No. of Channel |
8 separate channel with individual adjustment of delay and gain control. |
Display |
LCD Display 16x2 Alphanumeric for indication of parameter value. |
Gain |
Adjustment from -10dB to 30dB in step of 1db increment for each channel. |
Delay |
Adjustment from 0 to 99mm in step of 1mm increment for each channel. |
Memory |
10 calibration set-up can be store/recall. |
Operating Mode |
Factory set T+R / T-R internally selected. |
Channel Status Indication |
8 LED’s for indication of on/off status of channel. |
Keyboard |
Sealed membrane keyboard with direct access key for channel selection. |
Battery |
Li-Ion battery pack 14.4VDC, 4Ah, gives 8 hours continuous operation from fully charged battery. Full charging is done within 4.5 hours. |
Operating temperature |
0 to 55° C. |
Dimensions |
152 x 255 x 70(HxWxD). |
Weight |
1.8 KG. |