Technical Specification - ( EHC -09DL CW, EHC-09 CW, and EHC-09 C ) |
Thickness Range |
0.008-20 inches (0.20 mm- 508 mm), depending on material, temperature and transducer selection. |
Material Velocity Calibration Range |
0.0200-0.7362 in/µS ( 0.508-18.699 mm/µS ) |
Temperature |
Gage Operating:-4°Fto122°F(-20°C to 50°C) Surface temperature of material Depending on probes use, from -5° F to 1000°F (-20°C to 537°C). |
Battery life |
Up to 50 hours (25 hours with backlight on). |
Battery type |
2 "AA" Alkaline. |
Colour Display |
170 X 220 pixel, high resolution TFT colour display. |
Information displays |
LOS,min,max,large reading while displaying min at the same time, velocity, zero, calibration, units, freeze, unfreeze, %battery life remaining, gain-low, std, high, echo to echo symbol. |
Resolution |
.001"( .01 mm. ) |
Auto Probe Setup Parameters |
Via pick list from a menu to set up gain,V-path and sensitivity |
Delay line zero measurement |
Auto at power up with listed numeric value. Ideal for correcting delay line wear/curvature and for transducer acoustic drift at elevated temperatures. |
Package |
Custom, splash-proof, high impact plastic with illuminating rubber keypad for go/no-go testing.. |
Bandwidth |
0.5-20 MHz (-3dB). |
Units |
English/Metric/Microseconds. |
Gain |
Low, Standard and High for varying test conditions. |
Measurement rate |
4 or 20 measurements per second. |
Differential Mode |
Displays the difference from the actual thickness measurement and a user entered reference value. |
Alarms |
Minimum/Maximum depth, vibralarm, beeps and display flashes as well as keypad illumination. |
IIluminatig keypad |
F1 = Red, F2 = Yellow and F3 = Green for easy, go/no-go testing. |
Automatic probe wear indicator (Transducer attendant) |
Automatically informs the operator to replace the transducer (Patent pending). |
Ergonomics |
User selectable lefty or rightly display changes via keypad (Patent Pending). |
Backlight |
Light Emitting Diode (LED), On/Off or Auto On based on valid readings or last key press. |
Shut off |
Auto, time out (user programmable from 5-31 minutes or Never shut off). |
Fast Scan Min/Max mode |
Displays minimum or maximum thickness value at 20 measurements per second (ideal for high temperature thickness reading and tracking the minimum depth) while also displaying actual thickness. |
| Protective Pouch |
Custom molded pouch with belt clip and wrist strap for either lefty or righty operators |
| Carrying case |
Hard Plastic with high density molded cut out for all accessories |
Freeze mode |
Freezes display to hold onto last reading (ideal for high temperature application). |
Hold mode |
Holds display to retain last thickness reading in reverse video display. |
| Standard EHC-09 Wave Serices Includes |
Ultrasonic thickness gage with 5MHz, 0.375 inch diameter transducer with potted cable, operational manual, cable, couplant and protective pouch. |
| Warranty |
Limited 2 year warranty on parts and labor |
Size ( mm ) |
5"(127)(L) x 3"(76.2mm)(W) x 1.25" (31.75mm)(H). |
Weight |
8 OZ (0.23 kg ). |